Our eternal pursuits are the attitude of “regard the market, regard the custom, regard the science” as well as the theory of “quality the basic, believe in the 1st and management the advanced” for Vs1 12kv draw out type Vcb for High Voltage Switch 10kvIndoor Hv Vacuum Circuit BreakerOperating Mechanism in Switchgear, We warmly welcome clients, enterprise associations and pals from all around the earth to get in touch with us and seek out cooperation for mutual added benefits.
Our eternal pursuits are the attitude of “regard the market, regard the custom, regard the science” as well as the theory of “quality the basic, believe in the 1st and management the advanced” for12kv Vacuum Circuit Breaker,12kv vsg vcb,China Vsg 12kv,High Voltage Indoor Vacuum Circuit Breaker,Indoor Breaker,Indoor Circuit Breaker,Indoor High Voltage Vacuum Breaker,Indoor Hv Vacuum Circuit Breaker,Indoor VCB,Indoor Vcb,Three Phases Hv Indoor Circuit Breaker,Vacuum Circuit Breaker,Vacuum Circuit Breaker 12kv Indoor, Many kinds of different solutions are available for you to choose, you can do one-stop shopping here. And customized orders are acceptable. Real business is to get win-win situation, if possible, we would like to deliver more support for customers. Welcome all nice buyers communicate details of solutions with us!!
VSG-12 indoor HV vacuum circuit breaker is a 3-phase AC 50Hz 12kV indoor switch equipment.

♦ Installation way: withdrawable type, fixed type;

♦ Operating mechanism: spring operating mechanism;

♦ Pole type: assembled pole, embedded pole;

♦ Phase-to-phase distance: 150mm, 210mm, 275mm;

Environmental Conditions

♦ Ambient temperature: -15r~+40r;

♦ Altitude:

♦ Relative humidity: daily average ;

♦ Earthquake intensity:

♦ Places without fire, explosion hazard, serious filthy, chemical corrosion, as well as intense vibration.

Main Technical Parameters

No

Item

Unit

Value

1 Rated voltage

kV

12

2 1 min power frequency withstand voltage

42

3 Rated lightning impulse withstand voltage

75

4 Rated frequency

Hz

50

5 Rated current A

630, 1250, 1600, 2000, 2500,

3150

6 Rated short circuit breaking current

kA

25, 31.5, 40

7 Rated short time withstand current

25, 31.5, 40

8 Rated short circuit duration s

4

9 Rated peak value withstand current

kA

63, 80, 100

10 Rated short circuit making current

63, 80, 100

11 Secondary circuit power frequency withstand voltage (Imin) IN

2000

12 Rated single / back-to-back capacitor bank breaking current A

630/400 (800/400 for 40kA)

Opening time (rated voltage)

ms

20-50

14

Closing time (rated voltage)

ms

35-70

15

Mechanical life

Times

10000

16

Electrical life

E2 class

17

Moving and fixed contacts cumulative allowed wear thickness mm

3

18

Rated closing operating voltage IN

AC/DC110/220

19

Rated opening operating voltage

 

No

Item

Unit

Value

20

Motor rated power

IN

90

twenty one

Charging time

s

≤15

twenty two

Clearance between open contacts

mm

9±1

twenty three

Over travel

mm

3±1

twenty four Contact closing bounce time

ms

≤2

25

Three phase opening and closing asynchronism

ms

≤2

26 Average opening speed

m/s

0.9-1.7

27 Average closing speed

m/s

0.6~1.0

28

Main conductive circuit resistance

≤45 (630A) ≤35(1250-2000A)

≤25(above 2500A)

29 Closing contact pressure of the contacts N

3100-3700 (25-31.5kA)

4400-4800 (40kA)

30 Rated operating sequence

O-0.3s-CO-180s-CO

Note: when current is 4000A, need forced air cooling.

General Structure Drawing and Installation Size (unit: mm)

Draw out type (assembled pole)

w1

cabinet width

rated current (A)

rated short circuit breaking current (kA)

P H A

B

C

D

AND

F

G

J

K

L

M

N

R

S

T

650

630

20'31.5

150 275 490 502 492 500 433 626 035 280 598 76 78 637 501 202 40
650 12j0

20-31.5

150 275 490 502 492 500 433 626 049 280 598 76 78 637 501 202 40

800

630

20-31.5

210 275 638 652 640 650 433 626 035 280 598 76 78 637 501 277 40
800 1250

20-40

210 275 638 652 640 650 433 626 049 280 598 76 78 637 501 277 40
800 1600

31.5-40

210 275 638 652 640 650 433 626 055 280 598 76 78 637 501 277 40
WOO 030

20-31.5

275 275 838 852 838 850 433 626 035 280 598 76 78 637 501 377 40
1000 1250

20-40

275 275 838 852 838 850 433 626 049 280 598 76 78 637 501 377 40
1000 1600

31.5-40

275 275 838 852 838 850 433 626 055 280 598 76 78 637 501 377 40
1000 1600-2000

31.5-40

310 310 838 852 838 850 361 680 079 295 586 77 88 698 529 377

0

1000 2500-4000

31.5-40

310 310 838 852 838 850 361 680

0109

295 586 77 88 698 529 377 0

♦ Draw out type (embedded pole)

w2

G

J

K

L

M

N

R

S

T

0)35 280 598

76

78

637 501

202

40
①49 280 598

76

78

637 501

202

40
035 280 598

76

78

637 501

277

40
①49 280 598

76

78

637 501

277

40
(D79 295 586

77

88

698 509

377

0

0109 295 586

77

88

698 509

377

0

Fixed type (assembled pole)

w3

A

B

C

AND

F

G1 G2

J

K

520

520

588

580

72

I

237

462

720

720

770

580

72

I

237

462

650

720

770

632

85

II

252

472

♦ Fixed type (embedded pole)

q1 q2Our eternal pursuits are the attitude of “regard the market, regard the custom, regard the science” as well as the theory of “quality the basic, believe in the 1st and management the advanced” for Reasonable price Vs1 12kv Type Handcart Vcb for High Voltage Switch 10kvIndoor HvVacuum Circuit BreakerOperating Mechanism in Switchgear, We warmly welcome clients, enterprise associations and pals from all around the earth to get in touch with us and seek out cooperation for mutual added benefits.
Reasonable price China Vsg-12kv/24kv, Many kinds of different solutions are available for you to choose, you can do one-stop shopping here. And customized orders are acceptable. Real business is to get win-win situation, if possible, we would like to deliver more support for customers. Welcome all nice buyers communicate details of solutions with us!!
VSG-12 indoor HV vacuum circuit breaker is a 3-phase
AC 50Hz 12kV indoor switch equipment.
♦ Installation way: withdrawable type, fixed type;
♦ Operating mechanism: spring operating mechanism;
♦ Pole type: assembled pole, embedded pole;
♦ Phase-to-phase distance: 150mm, 210mm, 275mm;


  • Previous:
  • Next: