Application
* Connect single-phase or three-phase insulated cables to transformers, switchgears, branch boxes and other equipment through 630A prefabricated connectors.
* Suitable for indoor and outdoor installation.
* Rated voltage: 8.7/15kV, 18/24kV
* Continuous rated current 630A; (900A overload can last for 8 hours)
* Extendable (JBK) rear connector or (HBLQ) series surge arrester to achieve multi-channel installation or provide overvoltage protection.
* Cable characteristics:
-Copper or aluminum conductor
-Has semi-conductive or metal shield
-Cable conductor cross section: 12kV 25-500mm2, 24kV 25-500mm2
Type Description
Feature
* When mated with a suitable bushing or plug, it provides a fully shielded and fully sealed detachable connection;
* Can be operated under water and other harsh conditions for a long time;
* The built-in capacitance test point is used to determine the charged state of the circuit, and must be used in conjunction with the charged display;
* No requirements for minimum safety distance between phases;
* The installation can be vertical, horizontal or any angle
Product Structure
1. Double-headed bolts: Metal bolts ensure that the conductor and the bushing are tightly matched.
2. Insulation layer: unique formula and mixing technology ensure the high quality of prefabricated insulating silicone rubber.
3. Insulator: The epoxy resin insulator contains threaded metal parts to ensure a close fit with the stud bolts.
4. Inner semiconducting layer: Prefabricated conductive silicone rubber effectively controls electrical stress.
5. Stress cone: Stress cones of different sizes are used with cable joints to ensure water sealing and cable stress relief.
6. Grounding eye: pre-injected into the outer shield for the connection of the grounding wire.
7. Outer semiconducting layer: The prefabricated conductive rubber overlaps with the cable shielding layer to make the shielding continuous and ensure that the outer semiconducting layer is grounded.
8. Crimping terminal: All-copper or copper-aluminum crimping terminal is suitable for copper or aluminum conductor.
Installation
* No special tools, straps or padding required;
* The cable connector is energized and operated immediately after being installed to the relevant parts;
* Provide regular assembly parts and installation manual.
* (Please contact our company for special requirements)
Standard Packaging
European style front joint body | utility knife |
stress cone | band Aid |
insulator | cleaning paper |
dust cap | silicone grease |
crimp terminal (copper or copper aluminum) | gloves (white, yellow) |
gloves (disposable) | |
socket wrench | sealant (red) |
M16/12 double-head screw | nylon cable tie (buckle) |
M12 nut, flat washer, spring washer | PVC electrical tape (red yellow, green) |
tape | certificate of quality |
sandpaper | installation instruction manual |
12KV Cable Type Configuration Table
Product model | Conductor cross section (mm2) | Cable insulation outer diameter (mm) | Cable type | Corresponding code |
JB-12/630-25 | 25 | 16.6 | 8.7/15 | 0 |
JB-12/630-35 | 35 | 17.6 | 8.7/15 | A |
JB-12/630-50 | 50 | 19 | 8.7/15 | A |
JB-12/630-70 | 70 | 20.6 | 8.7/15 | A |
JB-12/630-95 | 95 | 22.2 | 8.7/15 | B |
JB-12/630-120 | 120 | 23.6 | 8.7/15 | B |
JB-12/630-50 | 150 | 25.5 | 8.7/15 | C |
JB-12/630-185 | 185 | 26.7 | 8.7/15 | C |
JB-12/630-240 | 240 | 29 | 8.7/15 | D |
JB-12/630-300 | 300 | 31.2 | 8.7/15 | D |
JB-12/630-400 | 400 | 34.4 | 8.7/15 | AND |
JB-12/630-500 | 500 | 37.2 | 8.7/15 | F |
24KV Cable Type Configuration Table
Product model | Conductor cross section (mm2) | Cable insulation outer diameter (mm) | Cable type | Corresponding code |
JB-24/630-35 | 35 | 18.6 | 18/20 | B |
JB-24/630-50 | 50 | 19.6 | 18/20 | B |
JB-24/630-70 | 70 | twenty one | 18/20 | B |
JB-24/630-95 | 95 | 22.6 | 18/20 | C |
JB-24/630-120 | 120 | 24.2 | 18/20 | C |
JB-24/630-150 | 150 | 25.6 | 18/20 | D |
JB-24/630-185 | 185 | 27.2 | 18/20 | D |
JB-24/630-240 | 240 | 28.7 | 18/20 | AND |
JB-24/630-300 | 300 | 311. | 18/20 | AND |
JB-24/630-400 | 400 | 33.2 | 18/20 | F |
Note: The outer diameter of the cable is the decisive factor when selecting the model, and the conductor cross section is the reference.